Welcome to visitShanghai Chinon medical Model & Equipment Manufacturing Co., LTD

Phone:+86 13383897707 Tel:+86-0379-65160607 Email:chinonmed@adaanatomy.com

NEWS


Homepage:HOME> NEWS> NEWS

Newborn Lumbar Puncture: A Step-by-Step Drill with CK34001

Date:2026-11-27      Author:Shanghai Chinon medical Model & Equipment Manufacturing Co., LTD

Newborn Lumbar Puncture: A Step-by-Step Drill with CK34001

The BIX-CK34001 is a life-size newborn manikin built for one procedure: lumbar puncture. It positions the infant in lateral decubitus with the head flexed to the chest and the knees drawn up, offers a palpable L3–4 interspace, and gives a "pop" plus simulated cerebrospinal fluid when the needle lands correctly. That combination — landmark, resistance change, fluid return — is what makes a task trainer useful rather than decorative.

Quick answer: CK34001 is a life-size neonatal lumbar puncture trainer with L3–4 puncture site, spinous process and posterior superior iliac spine landmarks, realistic pop and simulated CSF outflow. Spare spinal canal and puncture needle included. Reference price US $235.68.

Why neonatal LP needs a dedicated trainer

Lumbar puncture in a neonate is a different procedure from the adult version. The landmarks are smaller, the safe window is narrower, and the consequences of a dry tap or a traumatic tap are clinically significant. Kessler's chapter on simulation for infant lumbar puncture training (Neonatal Simulation, 2021) and Shafer's programme abstract on neonatal LP simulation (2013) both describe the same problem: learners need repetition on something that gives feedback, and adult trainers do not reproduce infant proportions.

A general nursing manikin with a lumbar puncture feature can be used, but it is usually a secondary function on a full-body model. The CK34001 is the opposite: a single-purpose trainer with a replaceable spinal canal. That trade-off — less realism in the limbs, more durability at the puncture site — is the right one for a procedure lab.

The six-step drill

Run this as a 25-minute station, two learners per manikin.

  1. Position. Left lateral decubitus, head flexed to chest, knees to abdomen, back at the edge of the bed. Say out loud why over-flexion can compromise the airway.
  2. Landmark. Find the posterior superior iliac spine on both sides, draw an imaginary line, and identify L3–4 below it. The model has a palpable interspace for this step.
  3. Prepare. Sterile field, anaesthetic wheal, and a plan for what happens if the first attempt fails.
  4. Insert. Bevel up, slight cephalad angulation, advance slowly. Stop at the resistance change — the model reproduces the pop.
  5. Confirm. Fluid return confirms position. If no fluid, withdraw to subcutaneous, reassess landmarks, and redirect rather than probe.
  6. Close out. Dressing, documentation, and a verbal handover of the number of attempts.

The model can also be placed in a sitting position. Use it that way only after the lateral approach is reliable, because the sitting position changes the landmark geometry and novices tend to lose the midline.

Consumables and durability

ItemDetailPractical note
Puncture siteL3–4 lumbar interspaceSingle site; repeated use concentrates wear
FeedbackPalpable pop, simulated CSFFluid return is the objective end point
Spare partsSpare spinal canal, spare needleConfirm quantity per unit at order
PositionLateral decubitus or sittingSitting reserved for advanced practice
PriceUS $235.68 referenceFreight separate; quantity-tiered

Ask the supplier how many punctures a canal is rated for. The page lists a spare canal but not a cycle count, and the cycle count is what determines your annual consumable budget. That question, plus the needle gauge supplied, should go to chinonmed@adaanatomy.com before you standardise the station.

Teaching points the model cannot make

It will not simulate a bloody tap, a dry tap due to dehydration, or an infant who desaturates during flexion. Those are debrief topics, not manikin features. Pair the drill with a short case discussion: a 5-day-old with fever and lethargy, two failed attempts, and a decision to proceed to imaging. The model gives the hands; the case gives the judgement.

Sinha's chapter on lumbar puncture in the neonate (Manual of Neonatal Procedures, 2016) is a compact reference for the landmark logic and the contraindications, and it is worth putting on the station table rather than in a reading list nobody opens.

Setting up a station for eight learners

Two manikins, one facilitator, 25 minutes per pair, plus a five-minute debrief per pair. That is roughly two hours for eight learners, which fits a single afternoon. Keep one manikin set up in the sitting position for the demonstration and one flat for practice, so learners see both without re-positioning mid-session.

FAQ

Q1. Is the manikin full body or partial? It is a life-size infant designed for lumbar puncture, positioned laterally; the page focuses on the puncture site rather than limb articulation.

Q2. Does it produce actual fluid? It produces simulated cerebrospinal fluid outflow when the needle reaches the correct position.

Q3. Can it be used for other neonatal procedures? No. It is a dedicated LP trainer. Use a full-function infant manikin for intubation, umbilical access or CPR.

Q4. What spare parts are included? A spare spinal canal and a puncture needle, per the product description. Confirm quantities per unit.

Q5. How many uses before the canal needs replacing? The page does not state a cycle rating. Ask the supplier for the tested puncture count.

Q6. What is the price and lead time? US $235.68 reference per unit. Lead time depends on stock and destination; request it with the quotation.

Ordering notes

Reference price: US $235.68. Product page: BIX-CK34001 newborn waist puncture manikin. Catalogue: clinical models. More procedure guides: news.

Cycle-life data and spare-part pricing: chinonmed@adaanatomy.com.

References

  1. Kessler D. (2021). Simulation for Infant Lumbar Puncture Training. Neonatal Simulation. https://doi.org/10.1542/9781610022613-ch7
  2. Sinha A. (2016). Lumbar Puncture in Neonate. Manual of Neonatal Procedures. https://doi.org/10.5005/jp/books/12796_15
  3. Shafer J. (2013). Neonatal lumbar puncture simulation. Simulation in Healthcare. https://doi.org/10.1097/01.sih.0000441518.25817.1c
NEXT:CK20137 Wrist Puncture Model: How 3-Colour Feedback Works
LAST:LV10 Surgical Skills Kit Review: What the Modules Cover

Return list