Welcome to visitShanghai Chinon medical Model & Equipment Manufacturing Co., LTD
The BIX-H72 is a transparent adult male torso built for parenteral alimentation training: the internal jugular and subclavian channel are visible through the shell, the right chest has a cutaneous puncture covering, and the heart opens to show the tricuspid valve marked in red. The page price is US $662.86. It is a landmark-and-catheter model, not a bleeding or ultrasound-compatible simulator.
Quick answer. The H72 earns its price when a nursing or nutrition team must see, at the same moment, where the needle is and which vessel it has entered. It cannot teach ultrasound-guided puncture, it does not bleed, and it cannot be used to practise tip positioning under fluoroscopy.
| Item | Specification | Teaching consequence |
|---|---|---|
| Model | BIX-H72 parenteral alimentation nursing model | Built around central venous access, not general anatomy |
| Outer shell | Transparent, adult male proportions | Needle path is visible from outside the torso |
| Exposed channels | Internal jugular vein and subclavian venous channel | Both standard CVC routes can be demonstrated |
| Chest site | Cutaneous covering on the right side | Puncture practice with a replaceable skin layer |
| Cardiac detail | Heart opens; tricuspid valve marked in red | Explains why catheter tip position is checked |
| Reference price | US $662.86 | Priced as a teaching station, not a consumable |
A conventional torso teaches the student to find a landmark and hope the needle landed where the textbook says. The H72 removes the hope: because the shell is clear, the tutor can see the needle tip travel through the subcutaneous layer and enter the venous channel, then correct the angle in the same attempt.
That immediate visual feedback is the whole value of the product. It converts a procedure that is normally assessed after the fact — by chest film or by complication — into a procedure assessed in real time.
The red-marked tricuspid valve is a second teaching point. Trainees memorise "tip at the cavoatrial junction" without seeing why. Opening the heart and pointing to the valve makes the target physical: the tip must sit above this structure, not inside it.
One torso supports two students at a time; a group of eight rotates in four pairings inside a two-hour lab.
Central venous access for parenteral nutrition carries a measurable infection burden. A review of catheter care in parenteral nutrition set out the care bundle that reduces it, and a series of 447 home parenteral nutrition patients documented the complication profile that training must anticipate.[1][2] Biofilm formation on the catheter is the mechanism that makes hub discipline and dressing technique worth rehearsing rather than describing.[3]
That is why the H72's replaceable cutaneous covering matters: dressing technique is a psychomotor skill, and it degrades when it is only demonstrated.
Email chinonmed@adaanatomy.com for the covering price, accepted catheter gauges and a photograph of the open heart section.
| Field | Value on the product page |
|---|---|
| Product number | BIX-H72 |
| Category | Nursing skill models |
| Age and sex | Adult male proportions |
| Key routes | Internal jugular vein, subclavian venous channel |
| Reference price | US $662.86 |
| Certification | ISO 9001, ISO 14001, ISO 45001 factory certification |
Q1. What does "transparent design" mean in practice? The outer shell is clear, so bones, vessels, heart and part of the lungs are visible from outside, and the needle path can be watched during puncture.
Q2. Which central line routes can be taught? Both the internal jugular vein and the subclavian venous channel are modelled and visible.
Q3. Can it be used with ultrasound? No. There is no ultrasound-compatible tissue layer, so guided puncture must be taught on a different model.
Q4. Does the heart open? Yes. The heart section opens and the tricuspid valve is marked in red, which supports tip-position teaching.
Q5. What is the reference price? US $662.86 per unit before freight; confirm the current price and consumable costs with the supplier.
Q6. Is the chest covering replaceable? The right chest puncture site has a cutaneous covering. Ask the supplier to confirm whether it is supplied as a separate consumable and its unit price.
Contact. For consumable pricing, catheter-gauge compatibility or a teaching-department quotation, email chinonmed@adaanatomy.com. Product page: https://www.chinonmed.com/nursing-model/parenteral-alimentation-nursing-model-H72 · Nursing skill models: https://www.chinonmed.com/nursing-model · All articles: https://www.chinonmed.com/neslist.html
|
NEXT:BIX-HS4: Hand Vein Cannulation With Instant Error Feedback
LAST:NULL |